9 Additional Images

AEN110NuTone InVent™ Series Single-Speed Fan 110 CFM, 1.3 Sones, ENERGY STAR® certified product

  • Overview
  • Video Links
  • Specifications
  • Accessories
  • Reviews
  • Answers
  • This patent-pending series marks a revolution of our mid-range ventilation fans. It gives professionals the flexibility to handle new construction or room-side retrofit installations from one hard-working product line with a full range of operating points. Innovations include foldable mounting ears and new damper and housing technology that improve building airtightness like never before. And all with new grille designs that are at home in any decor.

    • 110 CFM reduces humidity to quickly eliminate fogged mirrors and manage moisture in bathrooms up to 105 square feet, so your vision will always be clear and your surroundings will always be comfortable
    • Retrofit installations can be done entirely from the room-side – no attic access required. This means a faster, easier installation, so you can move on to something else
    • With our TrueSeal™ Damper Technology, InVent fans reduce air leakage by up to 50%* compared to competitive models, resulting in better home performance via blower door tests and reducing cold and warm air backdrafts
    • EzDuct™ Connector can be installed room-side with no attic access required, fan housing connection have never been easier
    • ENERGY STAR® Certified
    • UL Listed for use over tubs and showers with a GFCI circuit; so you can capture the steam before it spreads throughout the room by locating your fan exactly where you need it the most

    *Testing reflects total fan housing airtightness. See nutone.com/invent for more details.

  • Video Links

    NuTone InVent Series Features & Benefits Video

    NuTone InVent Series How To Install

    Older Homes and Indoor Air Quality

    Indoor Air Quality: Passions

    Spot Ventilation Can Improve the Indoor Air Quality in Your Home

    Selecting Proper Ventilation Fan Size is Easy - Danny Lipford

    What are CFMs? - Danny Lipford

    How long can the venting for my bath vent be? Can I use flexible duct? - Danny Lipford

    Cleaning a Bath Exhaust Fan - Danny Lipford

    Proper Ventilation Equals A Healthy Home - Danny Lipford

    How To Ventilate The Whole House - Danny Lipford

    Article Links

    Evacuate the Bathroom

    Breathe Easy – What you need to know to ensure proper home ventilation

  • Bathrooms up to (X) Square Feet105
    Ceiling InstallationYes
    CFM @ 0.10"110
    CFM @ 0.25"92
    ColorWhite
    CSANo
    cUL ListedNo
    Duct DirectionHorizontal
    Duct Size4"
    ENERGY STAR® certified productYes
    Globe ColorN/A
    Grille FinishWhite Polymeric
    Grille Length11-1/4"
    Grille Width12"
    Heater WattageN/A
    Housing Dimension LxWxH9-1/4" x 10" x 5-3/4"
    Housing Height5-3/4"
    Housing Length9-1/4"
    Housing Width10"
    Humidity SensingNo
    HVI CertifiedYes
    Light Bulb QuantityN/A
    Light Bulb WattageN/A
    Light Bulbs IncludedNo
    Lighting TypeNo Light
    Minimum construction space required2" x 6"
    Motion SensingNo
    Motor engineered for continuous operationYes
    NightlightNo
    Product Weight (Pounds)10.0
    Project PackNo
    Radiation Damper AvailableYes
    Rated Amps0.3
    Rated Sones1.3
    Rated Watts23.4
    Room-Side InstallationYes
    UL Listed for use over bathtubs or showers when connected to a GFCI circuitYes
    Wall InstallationNo
    Warranty3 Years
    Watts @ 0.1"23.4
  • compare to ls100se

    My LS 100SE motor is not running after bumping on. LS 100SE motor replacement discontinued. Need replacement unit to fit in same rough opening.
    Asked by: John Stevens
    Thank you for your question on the model LS100SE and AEN110 exhaust fans. The AEN110 would be a suitable replacement for the LS100SE. The LS100SE required a ceiling opening of 9-3/8” x 11-1/4” and the AEN110 requires an opening of 9-1/4” x 10”. You will need to completely remove the LS100SE from the ceiling to install the new unit, but if you have access from above, an attic or crawl space, the change out should not be difficult.
    Answered by: NuToneCustomerService
    Date published: 2015-11-25

    In the specification sheet where it says "project pack" then "no" are there other parts I will need to complete the installation?

    Other fans in this model series say "yes" so how does this effect what additional I may need for each one?
    Asked by: CH
    Thank you for your question on the model AEN110 exhaust fan. The AEN110 is a complete model. We do sell project packs for some models, usually used by contractors, where they would get a rough-in project pack to install a number of unit housings when the house is being built. After the house is built, they would then purchase the finish project packs to install into the unit housings that were previously installed.
    Answered by: NuToneCustomerService
    Date published: 2016-07-25

    How will this compare to the QTRN110?

    Will this replace the QTRN110? Or is there a better replacement for the QTRN110 that is going to be available.
    Asked by: Questionier
    Thank you for your question on the models QTRN110 and AEN110 exhaust fans. The AEN110 is the replacement for the QTRN110, but if you currently have a QTRN110, you will need to completely remove it from the ceiling to install the AEN110. The AEN110 will be slightly quieter but it will only draw 1/3 of the current that the QTRN110 draws.
    Answered by: NuToneCustomerService
    Date published: 2015-10-14
    • y_2017, m_11, d_24, h_20CST
    • bvseo_bulk, prod_bvqa, vn_bulk_2.0.3
    • cp_1, bvpage1
    • co_hasquestionsanswers, tq_3
    • loc_en_US, sid_b5c56db2-a39f-4a07-bd46-693d173b012e, prod, sort_[SortEntry(order=LOCALE, direction=DESCENDING), SortEntry(order=FEATURED, direction=DESCENDING), SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]